N_031.mp4

: Fully retract the boom. Turn the potentiometer counter-clockwise until it stops to reset the "zero" point.

: Verify voltage at the sensor. Expected values are roughly 3.125V (0°) and 2.5V (45°) . 3. Pressure Transducer Maintenance

: If replacing the system chip, ensure the notch faces the correct direction to avoid frying the board. n_031.mp4

: Measure the signal between Pin 2 (signal) and Pin 1 (ground). Use a voltmeter at test point MP4 on the main board. 2. Angle Sensor Adjustment

Detailed wiring diagrams and flowcharts can be found in the PAT DS350 Service Manual or via WIKA Mobile Control Support . LENGTH-ANGLE-RADIUS-LOAD INDICATING SYSTEM : Fully retract the boom

: Reconnect hoses and bleed the air from the hydraulic lines to ensure accurate readings. ⚠️ Critical Safety Checks

The filename n_031.mp4 frequently appears in technical contexts related to crane systems, specifically associated with documentation for the DS 350 and EI 65 series Load Moment Indicators (LMI). Expected values are roughly 3

: Ensure the hoist limit switch stops the winch before the hook hits the boom tip.